PRODUCT CENTER

To provide customers with the world's most advanced testing instruments in the field of environmental geotechnical and material testing (including food engineering)

Home >> Product >>Nondestructive and material testing >> Soil particle size distribution observation system
Product Detail

Soil particle size distribution observation system

Collect
PRODUCT DESCRIPTION

    Working principle:

  Generally speaking, the soil particle size distribution observation system consists of several parts: optical path system, sample dispersion system, operation control system, light intensity detection system, data transmission processing system, etc. The monochromatic, coherent, and parallel beams emitted by the solid-state laser source pass through the beam processing unit and irradiate the sample particles to scatter. The scattered light is focused by a Fourier lens and then imaged on a series of detectors. The energy distribution of the scattered light is the same as that of the sample particles. The distribution of particle size is directly related. Through the data processing system, a suitable theoretical model is selected to obtain the particle size distribution of the tested sample.


  Modular design: a variety of dispersion systems are available, and dry and wet conversion is easy


                       image.png


  Complete configuration: optical measurement device, sample injection system, data processing software, computer/printer


                      image.png

  Technical features:

1. Patented technology: Patented fixed-position Tri-Laser solid-state light source design without any moving parts. The classical Fourier optical path is combined with the double receiving lens to receive the diffracted/scattered light signal of the particle at a large angle in real time;

2. Optical signal detection: no scanning is required, and the full-scale scattered light signal is synchronously accepted in real time to ensure high reproducibility of measurement results and high resolution in the full-scale range;

3. Accuracy: The first company to introduce "non-spherical" particle correction factor, built-in optical database of commonly used analytical materials, to improve the accuracy of test results;

4. Ultra-wide measurement range: "Bluewave" laser technology provides the best solution to ensure the stability of large-angle scattered light signals, making the measurement lower limit reach 0.01um, improving the accuracy and resolution of the test area;

5. Fully automatic operation: the system automatically detects the light, automatic background detection, automatic dilution, automatic measurement, automatic cleaning, man-machine dialogue, simple and practical, and reduces the influence of human factors;

6. The new and improved dry jet injector in 2008 has a maximum dispersion pressure of 8 atm. After the measurement is completed, it can automatically backflush to clean the pipeline, and the results are reproducible;

7. NISl standard material designated certification instrument.


  Technical indicators


Measuring range

0.01- 2800 μm

Basic type 0.7~1000 μm;

High-end type 2.7 carefully 00 μm;

Standard 0.25 but 1500 μm;


Special type 0.09-1500 μm;

Extended 0.02-2000 μm;

Enhanced 0.02-2800 μm;


Blue wave type 1 0.01- 2000 μm;

Blue wave type 2. 0.01~2800 μm;

*Welcome to customize a wider measurement range;


Analysis accuracy

Master 0.6%

repetitiveness

Master 0.5%

measure time

10-999 seconds

Disperse phase

water or organic solvent

Measurement principle

Static Laser Diffraction Method and Full-Scale Mie Theory

Laser system

Patented three-beam (Tri-Laser) solid-state diode laser, with "Bluewave" laser technology, expand the lower limit to 0.01μm

Detection angle

0.02-163。

Detector

151 detection cells, highly sensitive silicon photodiodes arranged in a logarithmically optimized manner

Signal Acquisition

No need to scan, accept full-scale digital optical signals in real time

Sample Dispersion System

A wide range of dispersion systems are available to convert from wet to dry in less than 2 minutes

Operating software

Flexibility: Compatible with Windows 98, 2000, NT, XP and 7 operating systems;

Report Format: Your integrals, numbers are and area distributions, including integral/derivative percentages and other analysis statistics. The output data is in the form of ODBC to ensure compatibility with other statistical analysis software and word processing software. Data integrity meets 21 CFR PART11 security requirements;


international standard

It fully complies with the international standard of IS013320-1 laser particle size analysis.

External ring mirror

Ambient temperature: 10-35℃

Relative Humidity: Kid 90%

Power Requirements: 90-240VAC, 5A, 50/60Hz


Host size

360Hx560Wx460D mm


image.png


image.png

 


WELCOME

Stay up to date with our new products, events and news

在线表单提交
More
Name
Telephone
Message
Technical Support: 亿企邦 | Admin Login
×
seo seo