Equipment Introduction:
This equipment primarily consists of four main components: a Large-Scale Landslide Physical Test Flume, a Fully Automated Artificial Rainfall Simulation Unit, a Reservoir Water Level Fluctuation Control Unit, and a Rear Edge Water Replenishment Unit.
The core of the system is the Large-Scale Landslide Physical Test Flume. The entire flume is 10 meters long, with an adjustable width ranging from 0.5 to 3 meters, and a height of 1.5 meters. It is divided into three sections to meet the needs of simulating various real-world topographies. Different types of soil combinations can be filled into the flume to simulate different slope scenarios.
A Fully Automated Artificial Rainfall Simulation Unit is installed above the flume. Spray units are arranged in the upper part of the channel to regulate rainfall amount, rainfall intensity, and precipitation coverage area, simulating natural rainfall with different characteristics. A Reservoir Water Level Fluctuation Control Unit is positioned at the lower end of the flume to control the rise and fall of the reservoir water level. A Rear Edge Water Replenishment Unit is set up at the back end of the upper section of the slope to control changes in slope water content and water level fluctuations. This enables three-dimensional physical simulation experiments of slope stability characteristics under hydrodynamic forces. The setup can also be used to study the triggering, flow, and evolution characteristics of debris flows in channels of different widths and morphologies.
Main Technical Specifications:
Large-Scale Landslide Physical Test Flume
Flume Dimensions: Three sections total, overall length 10 m, adjustable width range 0.5–3 m (0.5/1.5/3), height 1.5 m.
Slope Adjustment Range: 0–30° (resolution 0.1°).
Tilt Sensor: 0–90° (accuracy ≤ 1 arcsecond).
Fully Automated Artificial Rainfall Simulation Unit
Continuous Rain Intensity Adjustment Range: 1–150 mm/h (accuracy 1%).
Rainfall Measurement Accuracy: 0.2 mm/h (accuracy 3%).
Reservoir Water Level Fluctuation Control Unit
Water Level Fluctuation Height: Segmented control 0.1–0.5 m.
Groundwater Level Measurement: 0–100 m (accuracy 0.1% FS).