PRODUCT CENTER

To provide customers with the world's most advanced testing instruments in the field of environmental geotechnical and material testing (including food engineering)

Home >> Product >>Soil Environmental Testing >> TEROS 12 Soil Moisture, Temperature, Conductivity Sensor
Product Detail

TEROS 12 Soil Moisture, Temperature, Conductivity Sensor

Collect
PRODUCT DESCRIPTION

The TEROS12 soil moisture, temperature, conductivity sensor combines accuracy, economy, ease of use and reliability. The TEROS 12 sensor can be connected to METER's latest data acquisition, such as the ZL6, enabling plug-and-play sensor and cloud storage management of data.

Main feature:

Simultaneous measurement of soil volumetric water content (EWC), conductivity and temperature

The latest in fast conductivity measurement

Thermistor embedded in the middle probe

Full Moisture Measurement Range - Sensitively senses subtle changes in moisture content from 0 to 100% VWC

Minimizes salt and texture effects using capacitive technology at 70MHz

Special stainless steel probe for easy insertion into various soils and good contact

Filled with epoxy resin, it can be guaranteed to be buried in the field for more than 10 years

Suitable for all kinds of data acquisition, and the voltage output is easy to read

Technical indicators:

     399772bbc9af55fb6664fa3ebfbdb1d.png


Measurement frequency: 70 MHz

Output: DDI serial or SDI-12

Support data acquisition (sold separately): METER's ZL6, EM50/60 series; others provide 4.0~15VDC power supply, support serial communication or SDI-12 communication data acquisition

Dimensions: 9.4 cm x 2.4 cm x 7.5 cm

Probe length: 5.5 cm

Working environment: -40 ~ 60°C (sensors for higher or lower environments are available, please contact us if necessary)

Cable Length: Standard 5m. Other lengths can be customized, up to 75m.

Connector type: 3.5mm headphone plug or bare wire connector

Measuring volume: 1010 cm3

Measurement time: 25-50 ms (milliseconds)

Supply Voltage (VCC) to GND: 4.0 VDC Min; Typical: NA; 15.0 VDC Max

Digital Input Voltage (Logic High): Min: 2.8V; Typical 3.6V; Max: 3.9V

Digital Input Voltage (Logic Low): Min: -0.3V; Typical 0.0V; Max: 0.8V

Digital Output Voltage (Logic High): Min: NA; Typical: 3.6V; Max: NA

Power Line Conversion Rate: Min 1.0V/ms; Typical: NA; Max: NA

Current: 25ms During measurement: min. 3.0; typical 3.6mA;

Startup Time: DDI Serial: 80ms minimum; NA typical; 100ms maximum; SDI-12: NA minimum; 245ms typical; NA maximum

Follow the standard: produced under the ISO 9001:2015 standard;

EM ISO/IEC 17050:2010 (CE Mark)

2014/30/EU and 2011/65/EU

EN61326-1:2013 and EN55022/CISPR 22