PRODUCT CENTER

To provide customers with the world's most advanced testing instruments in the field of environmental geotechnical and material testing (including food engineering)

Home >> Product >>Soil Environmental Testing >> HYPROP 2 Soil Moisture Profile Meter (Wet End)
Product Detail

HYPROP 2 Soil Moisture Profile Meter (Wet End)

Collect
PRODUCT DESCRIPTION

Traditional methods of measuring soil moisture release profiles require responsible operations, are time-consuming, and may not obtain critical data points. The emergence of HYPROP 2 greatly improves the measurement efficiency and quality of soil moisture release curves. HYPROP 2 generates soil moisture profiles in the wet-end range in days rather than months, and this process is done automatically. If used in conjunction with WP4C, which can measure dry soil water potential, the soil moisture characteristic curve of the dry end can also be obtained, resulting in a complete curve.

In addition to this, the HYPROP 2 can also be used to measure the unsaturated hydraulic conductivity of the original soil in a 250mL soil ring. Use with KSAT to obtain hydraulic conductance curves for any soil type.

Measuring principle:

The HYPROP 2 monitors soil water potential through micro tensiometers installed in two locations, the entire measuring device is placed on a balance, records soil water potential and sample weight over time, calculates soil water content from sample weight, and plots water potential as a function of water content Change graph. More than 100 data points can be acquired in the range of 0 to -100kPa, the higher resolution and richer information are not comparable with traditional methods.

Main feature:

Precise and reliable, save time and effort, easy to operate

Simultaneous measurement of water retention and hydraulic conductivity

High water retention, especially near saturation

Hydraulic characteristics are derived from a large number of measurement data

Accurate and reliable determination of unsaturated hydraulic conductivity, independent of assumed models

Tensiometers measure beyond the typical void point, down to -240kPa

Tensiometer inverted in soil sample (undisturbed by evaporation, no effect on tensiometer axis)

Reduced moisture loss from the tensiometer after reaching the cavitation stage

      image.png

Technical indicators:

    image.png

    image.png