ATMOS 41 Integrated Weather Station
Collect
PRODUCT DESCRIPTION
Why choose ATMOS 41 Currently, the sensors in most weather stations are independent and expensive to install and maintain. Wiring and programming can be daunting to many, and figuring out the best placement for all the sensors on a weather station rack is a matter of careful consideration. Traditional integrated weather stations solve the above problems. However, in such an observation system, if one or more additional sensors are desired to be added, such as the measurement of soil profile moisture content, additional data acquisitions are usually required. "1+ many" solution METER's solution is "1 (integrated) + many (multiple independent sensors)". The data of the ATMOS 41 is transmitted via 1 cable. This means that when measuring meteorological parameters, only 1 channel of the data acquisition is occupied. Therefore, if you connect an ATMOS 41 to a ZL6 (6-channel) logger, you can add more METER sensors: for example, soil moisture sensors, etc. Main feature: The ATMOS 41 combines several weather sensors with no moving parts, making installation and maintenance very simple. In most integrated weather stations, the measurement of total solar radiation and precipitation can only be used for one or the other. The ATMOS 41 can monitor both parameters simultaneously. ATMOS 41 can work seamlessly with ZL6 data acquisition (6 channels), plug and play, and can store and manage data based on cloud servers. The entire process involves no wiring and no programming. Features: Measures multiple meteorological variables, including: air temperature, air relative humidity, water vapor pressure, atmospheric pressure, wind speed, wind speed extremes, wind direction, total solar radiation, precipitation, number of lightning strikes, and distance Easy to install No moving parts All data is transmitted via only 1 cable SDI-12 Digital Communication Data cloud management available via ZENTRA Cloud Technical indicators:
Size: Diameter 10cm, Height 34cm Cable length: 5m, other lengths can be customized, up to 75m Support data acquisition (sold separately): METER ZL6, EM60, EM60G, CSI data acquisition Supply Voltage (VCC to GND): Min 3.6VDC, Max 15.0VDC Digital Input Voltage (Logic High): Min 2.8V, Max 5.5V Typical 3.0V Digital input voltage (logic low): -0.3V min, 0.8V max, 0.0V typical Digital output voltage (logic high): 3.6V typical Power line conversion rate: 1.0V/ms minimum Current consumption (during measurement): min. 0.2mA, max. 33.0mA, typical 8.0mA Current consumption (during sleep): 0.2mA minimum, 0.4mA maximum, 0.3mA typical Working temperature: -50 ~ 60℃ Start time (SDI ready) aRx! Command: Typical 10s Start time (SDI ready) other commands: typical 800ms Measurement time: typical 110ms, maximum 3000ms Follow the standard: produced under the ISO 9001:2015 standard; EM ISO/IEC 17050:2010 (CE Mark)
|