ATMOS 41 Integrated Weather Station

Collect
PRODUCT DESCRIPTION

Why choose ATMOS 41

Currently, the sensors in most weather stations are independent and expensive to install and maintain. Wiring and programming can be daunting to many, and figuring out the best placement for all the sensors on a weather station rack is a matter of careful consideration.

Traditional integrated weather stations solve the above problems. However, in such an observation system, if one or more additional sensors are desired to be added, such as the measurement of soil profile moisture content, additional data acquisitions are usually required.

"1+ many" solution

METER's solution is "1 (integrated) + many (multiple independent sensors)". The data of the ATMOS 41 is transmitted via 1 cable. This means that when measuring meteorological parameters, only 1 channel of the data acquisition is occupied. Therefore, if you connect an ATMOS 41 to a ZL6 (6-channel) logger, you can add more METER sensors: for example, soil moisture sensors, etc.

Main feature:

The ATMOS 41 combines several weather sensors with no moving parts, making installation and maintenance very simple.

In most integrated weather stations, the measurement of total solar radiation and precipitation can only be used for one or the other. The ATMOS 41 can monitor both parameters simultaneously.

ATMOS 41 can work seamlessly with ZL6 data acquisition (6 channels), plug and play, and can store and manage data based on cloud servers. The entire process involves no wiring and no programming.

Features:

Measures multiple meteorological variables, including: air temperature, air relative humidity, water vapor pressure, atmospheric pressure, wind speed, wind speed extremes, wind direction, total solar radiation, precipitation, number of lightning strikes, and distance

Easy to install

No moving parts

All data is transmitted via only 1 cable

SDI-12 Digital Communication

Data cloud management available via ZENTRA Cloud

Technical indicators:

78f015b42ed3abf92e8d6fc2a9b2f32.png

187903ab37bf189a2a381d1afa2e755.png

Size: Diameter 10cm, Height 34cm

Cable length: 5m, other lengths can be customized, up to 75m

Support data acquisition (sold separately): METER ZL6, EM60, EM60G, CSI data acquisition

Supply Voltage (VCC to GND): Min 3.6VDC, Max 15.0VDC

Digital Input Voltage (Logic High): Min 2.8V, Max 5.5V Typical 3.0V

Digital input voltage (logic low): -0.3V min, 0.8V max, 0.0V typical

Digital output voltage (logic high): 3.6V typical

Power line conversion rate: 1.0V/ms minimum

Current consumption (during measurement): min. 0.2mA, max. 33.0mA, typical 8.0mA

Current consumption (during sleep): 0.2mA minimum, 0.4mA maximum, 0.3mA typical

Working temperature: -50 ~ 60℃

Start time (SDI ready) aRx! Command: Typical 10s

Start time (SDI ready) other commands: typical 800ms

Measurement time: typical 110ms, maximum 3000ms

Follow the standard: produced under the ISO 9001:2015 standard;

EM ISO/IEC 17050:2010 (CE Mark)